<!-- Source: https://docs.captron.com/trms/calis/diagnostics -->

# Self-Diagnosis and Errors

CALIS Level Sensors include the following diagnosis features:

- **Monitoring** of Supply and internal Voltages and MCU Temperature
- **Overload Detection** on digital and analog outputs

## Error Codes

<table>
  <thead>
    <tr>
      <th>Blink Code</th>
      <th>IO-Link Error Code</th>
      <th>Description</th>
    </tr>
  </thead>
  <tbody>
    <tr>
      <td>1</td>
      <td>0x0001</td>
      <td>Internal error</td>
    </tr>
    <tr>
      <td>2</td>
      <td>0x0002</td>
      <td>Error with intermediate voltage</td>
    </tr>
    <tr>
      <td>4</td>
      <td>0x0008</td>
      <td>Supply voltage overrun / underrun</td>
    </tr>
    <tr>
      <td>5</td>
      <td>0x0010</td>
      <td>Container overfill / Sensor error</td>
    </tr>
    <tr>
      <td>8</td>
      <td>0x0080</td>
      <td>Parameter memory error</td>
    </tr>
    <tr>
      <td>9</td>
      <td>0x0100</td>
      <td>Parameter error</td>
    </tr>
    <tr>
      <td>12</td>
      <td>0x0800</td>
      <td>LED error</td>
    </tr>
    <tr>
      <td>13</td>
      <td>0x1000</td>
      <td>Overload on digital output</td>
    </tr>
    <tr>
      <td>15</td>
      <td>0x4000</td>
      <td>Temperature overrun</td>
    </tr>
  </tbody>
</table>

## References

- [IO-Link Interface and System Specification V1.1.3](https://io-link.com/share/Downloads/Package-2020/IOL-Interface-Spec_10002_V113_Jun19.pdf)

## Revision History

### Rev. A – 2024-12-19

- Initial version