CANEO series5x – Firmware V1.x
Revision A | 2026-09-15
CANEO-series5x-TRM-en-2026-09-15.pdfIntroduction
CANEO series50 and series52 SENSORswitches can be used in IO-Link and in non-IO-Link environments, while CANEO series53 and series54 SENSORswitches are dedicated to IO-Link usage, only.
For non-IO-Link usage, the sensor features one or two standard Digital Outputs and up to two standard Digital Inputs (E1, E2), which can be used to control the sensor's LED (and text display).
The related parameters can be configured during deployment and commissioning via IO-Link:
- Behavior of the Touch Sensor
- Function of the Digital Output – PNP/NPN/PushPull, Normally Open/Closed
- Function of the up to two Digital Inputs (E1, E2)
- LED and display control
- Locking/release of Digital Output
- LED and display behavior for various states
If the sensor detects IO-Link communication, it automatically switches to the IO-Link communication mode. The IO-Link standard offers different communication mechanisms:
- Acyclic Data (Indexed Service Data Units): Used to set the sensor configuration during commissioning.
- Cyclic Process Data: Used to receive the sensor's state and influence its behavior during runtime.
- Events: The sensor will report events in case of error.
Process Data, ISDUs and events of the sensor, their respective numeric indices, offsets, and values, are described in the IODD file of the sensor. It is highly recommended to use this file when integrating the sensor in an application.
Revision History
Rev. A
- Initial version.