<!-- Source: https://docs.captron.com/trms/series5x/io-link-interface -->

# IO-Link Interface

The IO-Link Interface complies to IO-Link Specification V1.1.5 (October 2025).
https://io-link.com/fileadmin/user_upload/Downloads/Package_2025/IOL-Interface-Spec_10002_V1.1.5_Oct2025.zip

<table>
  <tbody>
    <tr>
      <th>Vendor ID</th>
      <td>1239</td>
    </tr>
    <tr>
      <th>Device Family</th>
      <td>CANEO SENSORbutton</td>
    </tr>
  </tbody>
</table>

<table>
  <thead>
    <tr>
      <th>Device Name</th>
      <th>CANEO series50 Touch</th>
      <th>CANEO series50 Touch Display</th>
      <th>CANEO series52 Duo-Touch</th>
      <th>CANEO series52 Duo-Touch Display</th>
      <th>CANEO series53 Multi-Touch</th>
      <th>CANEO series53 Multi-Touch Display</th>
      <th>CANEO series54 Multi-Touch</th>
      <th>CANEO series54 Multi-Touch Display</th>
    </tr>
  </thead>
  <tbody>
    <tr>
      <th>Device ID</th>
      <td>2820</td>
      <td>2816</td>
      <td>2821</td>
      <td>2817</td>
      <td>2822</td>
      <td>2818</td>
      <td>2823</td>
      <td>2819</td>
    </tr>
  </tbody>
</table>

## Communication Interface

<table>
  <tbody>
    <tr>
      <th>IO-Link Version</th>
      <td>V1.1</td>
    </tr>
    <tr>
      <th>Bitrate</th>
      <td>COM2</td>
    </tr>
    <tr>
      <th>Minimum Cycle Time</th>
      <td>14800µs</td>
    </tr>
    <tr>
      <th>Process Data Input Bits</th>
      <td>64</td>
    </tr>
    <tr>
      <th>Process Data Output Bits</th>
      <td>112</td>
    </tr>
    <tr>
      <th>SIO Supported</th>
      <td>
        Yes - for series50 and series52<br/>
        No - for series53 and series54
      </td>
    </tr>
    <tr>
      <th>ISDU Supported</th>
      <td>Yes</td>
    </tr>
    <tr>
      <th>Data Storage</th>
      <td>Yes</td>
    </tr>
    <tr>
      <th>Block Parameter</th>
      <td>Yes</td>
    </tr>
    <tr>
      <th>Supported Profiles</th>
      <td>FW-Update (49)</td>
    </tr>
  </tbody>
</table>