Measurement Mode

The device can indicate an analog measurement value that is presented as a voltage signal on E1 that ranges from 0V to VDC.

This display function is active only if no other scene is active according to the configured triggers (esp. "no touch" triggers).

The input voltage range will be linearly scaled to a displayed value range. The resolution of the value can be set and the value can be suffixed by a unit.

Depending on the displayed value, the LED ring will fill clockwise, starting at 12 o'clock.

Color and brightness of LED ring and number display are taken from Scene 1. (Hence, scene 1 should be configured without any triggers when using measurement mode.)

Alarms for high or low value can be configured. Using alarm thresholds and dedicated scene triggers, scenes can be configured to indicate these events on the LED ring.

Example: Container Fill level in 0.1 %

  • Input signal: 2 ... 10 V measurement signal
  • Displayed values: 0.0 ... 100.0 - fill level of a container in % with resolution 0.1
ParameterValueExplanation
Minimum Input Voltage (V)0Will map to Minimum Displayed Value (0.0)
Maximum Input Voltage (V)10Will map to Maximum Displayed Value (100.0)
Minimum Displayed Value0
Maximum Displayed Value1000100 [%] * 10 for resolution 0.1
Resolution0.1