<!-- Source: https://docs.captron.com/trms/series5x/touch-zones -->

# Touch Zones

CANEO series5x SENSORswitches offer one to four touch zones.

## Configuration options

For each zone, its behavior can be configured as follows.

- Sensor Mode (Dynamic / Static / Toggle / Toggle Exclusive)
- Touch Sensitivity (High / Middle / Low)
- Minimum Actuation Time
- Output Activation Delay
- Output Snap Time (for Static Mode)
- Output Minimum Impulse Time

For details, see the respective IO-Link ISDUs.

## Zone numbering

The touch zones 1 to 4 are enumerated depending on the product variant as follows.

<table>
  <thead>
    <tr>
      <th>Product Variant</th>
      <th>Zones</th>
      <th>Zone 1</th>
      <th>Zone 2</th>
      <th>Zone 3</th>
      <th>Zone 4</th>
    </tr>
  </thead>
  <tbody>
    <tr>
      <td>Cx50</td>
      <td><img src="/img/series5x-zones-cx50.svg" width="100" alt="Cx50 zone layout"/></td>
      <td>entire sensor area</td>
      <td></td>
      <td></td>
      <td></td>
    </tr>
    <tr>
      <td>Cx52H</td>
      <td><img src="/img/series5x-zones-cx52h.svg" width="100" alt="Cx52H zone layout"/></td>
      <td>upper half of sensor</td>
      <td>lower half of sensor</td>
      <td></td>
      <td></td>
    </tr>
    <tr>
      <td>Cx52V</td>
      <td><img src="/img/series5x-zones-cx52v.svg" width="100" alt="Cx52V zone layout"/></td>
      <td>left half of sensor</td>
      <td>right half of sensor</td>
      <td></td>
      <td></td>
    </tr>
    <tr>
      <td>Cx53D</td>
      <td><img src="/img/series5x-zones-cx53d.svg" width="100" alt="Cx53D zone layout"/></td>
      <td>lower half of sensor</td>
      <td>up left quarter of sensor</td>
      <td>up right quarter of sensor</td>
      <td></td>
    </tr>
    <tr>
      <td>Cx53L</td>
      <td><img src="/img/series5x-zones-cx53l.svg" width="100" alt="Cx53L zone layout"/></td>
      <td>left half of sensor</td>
      <td>up right quarter of sensor</td>
      <td>down right quarter of sensor</td>
      <td></td>
    </tr>
    <tr>
      <td>Cx53R</td>
      <td><img src="/img/series5x-zones-cx53r.svg" width="100" alt="Cx53R zone layout"/></td>
      <td>right half of sensor</td>
      <td>up left quarter of sensor</td>
      <td>down left quarter of sensor</td>
      <td></td>
    </tr>
    <tr>
      <td>Cx53U</td>
      <td><img src="/img/series5x-zones-cx53u.svg" width="100" alt="Cx53U zone layout"/></td>
      <td>upper half of sensor</td>
      <td>down left quarter of sensor</td>
      <td>down right quarter of sensor</td>
      <td></td>
    </tr>
    <tr>
      <td>Cx54</td>
      <td><img src="/img/series5x-zones-cx54.svg" width="100" alt="Cx54 zone layout"/></td>
      <td>up left quarter of sensor</td>
      <td>up right quarter of sensor</td>
      <td>down right quarter of sensor</td>
      <td>down left quarter of sensor</td>
    </tr>
  </tbody>
</table>

## Output link

On CANEO series50 and series52, touch zone 1 will operate Output 1 (Pin 4 on M12 connector / Pin 1 on milligrid connector / black wire).
If available on the series52 product variant, touch zone 2 will operate Output 2 (Pin 5 on M12 connector).