Events & Commands

Events

Event CodeTypeDefinition and recommended maintenance action
6144ErrorOutput Overload – Output current too high – max. 200 mA
16912WarningDevice temperature overrun – Clear source of heat
20496ErrorComponent malfunction – Repair or exchange
20752WarningPrimary supply voltage overrun – Check valid voltage range
20753WarningPrimary supply voltage underrun – Check valid voltage range
25376ErrorParameter error – Check datasheet and values

Commands

ISDU Index 2 – System Command

General Commands

ValueNameDescription
128Device ResetA warm start is triggered and the device will be set to an initial state. The communication will be interrupted by the device and then reinitiated by the master.
129Application ResetThe parameter of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master.
130Restore Factory SettingsThe parameter of the device are reset to factory settings. Note: A download of the data storage may be executed on the next power cycle and overwrite the factory default settings!
131Back-to-boxThe parameter of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port!

Calibration Commands

ValueNameDescription
164Calibrate Low LevelStores the current distance as Low Level reference point
165Calibrate High LevelStores the current distance as High Level reference point
167Set Additional Reference 1Stores the current distance as additional reference point 1
168Set Additional Reference 2Stores the current distance as additional reference point 2
169Set Additional Reference 3Stores the current distance as additional reference point 3
170Set Additional Reference 4Stores the current distance as additional reference point 4