IO-Link Interface
IO-Link Specification: V1.1.2 (July 2013)
| Property | Value |
|---|---|
| Device Family | Capacitive Sensors |
| Device Name | CANEO series10 |
| Device ID | 258 |
| IODD | IODDfinder |
Communication Interface
| Property | Value |
|---|---|
| IO-Link Version | V1.1 |
| Bitrate | COM2 |
| Minimum Cycle Time | 14800 µs |
| Process Data Input Bits | 80 |
| Process Data Output Bits | 64 |
| SIO Supported | Yes |
| ISDU Supported | Yes |
| Data Storage | Yes |
| Block Parameter | No |