Skip to main content

ISDU Indices

Access Rights: ro – Read Only, rw – Read/Write, wo – Write Only

System Command

NameIndexBytesAccessValuesDescription
System Command21wosee Events & Commands

Identification

NameIndexBytesAccessValuesDescription
Vendor Name1623roCAPTRON Electronic GmbH
Product Name18roCANEO series4x (Display)
Product ID1910roCx4xX-xxxx
Product Text2019roOrder-code
Symbol2763ro
Hardware Identification Key173429ro
Serial Number21ro
Firmware Version23roV5.x
Function Tag2532rw***

Activation Parameters

NameIndexBytesAccessValuesDescription
Sensor Mode2611rw1 - Toggle, 2 - Dynamic, 3 - StaticToggle: Touch to switch on, touch again to switch off. Can only be set back after "Output Minimum Impulse Time" is over. Dynamic: Output is on as long as "Output Minimum Impulse Time" is set; even though the user continues touching, the output will switch off. Static: Output is on until the user is no longer touching the sensor (but is at least on for the "Output Minimum Impulse Time").
Touch Sensitivity2601rw0 - High, 1 - Middle, 2 - LowHigh: required "Actuation Strength" > 4%. Middle: required "Actuation Strength" > 14%. Low: required "Actuation Strength" > 24%.
Glass Thickness2921rw1 - glass below 4mm / plexiglass below 2mm, 2 - glass 4mm to 7mm / plexiglass 2mm to 3mm, 3 - glass 8mm to 10mm / plexiglass 4mm to 5mmseries44 Glass devices only.
Minimum Actuation Time2632rw0 ... 65535 [ms]Time the sensor must be activated before output on Pin 4 switches, "Actuation Flag" is set to "Actuated" and "Actuation Count" goes up.
Minimum Actuation Time (Toggle OFF)2832rw0 ... 65535 [ms]Time the sensor must be touched in "Toggle" mode before output on Pin 4 turns OFF and "Actuation Flag" is set to "Idle".
Output Activation Delay3242rw0 ... 65535 [ms]Time the switching of the output is delayed when the sensor has been actuated.

I/O Parameters

NameIndexBytesAccessValuesDescription
Active Inputs2711rw3 - None (3 pin mode), 4 - Pin 2 (E1) (4 pin mode), 5 - Pin 2 (E1) and Pin 5 (E2) (5 pin mode)Controls which input pins are monitored.
E1/E2 Mode2721rw0 - Active Low, 1 - Active HighActive Low: Accepts a low signal as input to turn on. Active High: Accepts a high signal as input to turn on.
Output Locking3371rw0 - No locking, 1 - Release by E1, 2 - Release by E2, 3 - Release by E1 and E2Controls whether inputs E1/E2 must be active for the output signal on Pin4 to be ON when the sensor is touched.
Output Mode2731rw0 - NPN, 1 - PNP, 2 - PushPullNPN: Output signal is pulled down to 0V when output is on. PNP: Output signal is pushed up to +VDC when output is on. PushPull: Output signal is pushed up to +VDC when output is on and is pulled down to 0V when it is off.
Output NO/NC2741rw0 - NO (Normally Open), 1 - NC (Normally Closed)
Output Minimum Impulse Time2754rw10 ... 86400000 [ms]The minimal time (ms) of the output signal when the sensor is activated. The output signal cannot be interrupted. In toggle mode the sensor can only be deactivated after the minimal output signal length is over.

LED Parameters

NameIndexBytesAccessValuesDescription
LED Control Mode2931rw0 - Automatic Scene selection, 1 - Scene controlled by IO-Link Process Data, 2 - Advanced control by IO-Link Process DataSee LED & Display Control for details on each mode.
Adaptive LED Brightness2701rw0 - Off, 1 - OnIf turned "On" the sensor automatically adjusts the LED Brightness depending on the "Surrounding Brightness".
Manual LED Brightness3051rw0 ... 100 [%]Brightness of LED Ring and 7-Segment Display. Sets minimal brightness if "Adaptive LED Brightness" is turned "On".
Rotate Button3041rw0 - 0°, 1 - 180°Rotate LED Display – use if button is mounted upside down.
Boot Sequence3142rw0 - Off, 1 - Classic, 2 - CANEOOff: Immediately available. Classic: Countdown sequence. CANEO: CANEO sequence.

Custom Colors

Custom Color 1 (Index 306)

SubindexComponentValues
1R0 ... 255
2G0 ... 255
3B0 ... 255

Custom Color 2 (Index 307)

SubindexComponentValues
1R0 ... 255
2G0 ... 255
3B0 ... 255

Timer Parameters

NameIndex - SubindexBytesAccessValuesDescription
Timer Function322 - 11rw0 - disabled, 1 - count down, 2 - count up, 3 - count up infinitelyControls timer behavior.
Trigger Timer322 - 21rw0...7 - when entering Scene nTrigger to start timer. The timer starts when sensor enters/falls back into a certain scene.
Timer Timeout322 - 32rw0 ... 9999 [s]Time after which the timer stops.
LED Color323 - 11rw0 - CANEO, 1 - Red, 2 - Green, 3 - Blue, 4 - Yellow, 5 - Magenta, 6 - Cyan, 10 - Orange, 11 - Violet, 13 - Off, 14 - Clean Blue, 128 - Custom Color 1, 129 - Custom Color 2LED color during timer.
Timer LED Effect323 - 21rwSee LED Effects reference. Additionally: 24 - Timer Circle Clearing Clockwise, 25 - Timer Circle Clearing Counter-Clockwise, 26 - Timer Circle Filling Clockwise, 27 - Timer Circle Filling Counter-ClockwiseEffects 24–27 are synchronized with the timer.
Effect Frequency323 - 31rw1...60, 0 - Default Frequency [0.1 Hz]Frequency of LED effect in 1/10 Hz, range: 0.1 ... 6 Hz. Applies only for animated effects.

Observation & Diagnosis

NameIndexBytesAccessValuesDescription
Sensor Temperature2572ro-32768 ... 32767 [0.1 °C]
Supply Voltage2562ro0 ... 65535 [0.001 V]
Input E1 voltage2772ro0 ... 65535 [0.001 V]
Input E2 voltage2782ro0 ... 65535 [0.001 V]
MCU Voltage2792ro0 ... 65535 [0.001 V]
Charge Code2804ro0 ... 4294967295
Error Code2822ro0 ... 65535
Flash Erase Count2592ro0 ... 65535
Device Access Locks12rw