series10 supports four modes for controlling its LED:

  • Automatic Scene Selection
  • Scene controlled by IO-Link-Process Data *
  • Advanced Control by IO-Link Process Data *
  • Classic Two LED Mode

* If the SENSORswitch is not used with IO-Link, it will behave like with "Automatic Scene selection" mode.

The control mode can be selected via IO-Link parameter LED Control Mode (see ISDU Indices).

Automatic Scene Selection

Number of applicable scenes depends on parameter Active Inputs:

Active InputsScenes Used
None (3 pin mode)0, 1
Pin2 (E1) (4 pin mode)0 ... 3
Pin2 (E1) and Pin5 (E2) (5 pin mode)0 ... 7

Scene n is selected depending on the state of touch (sensor actuation) and the state of the input pins E1 and E2:

LED SceneTouchE1E2NonePin 2 (E1)Pin 2 (E1), Pin 5 (E2)
0000
1100
2010
3110
4001
5101
6011
7111

The active Scene is set according to the LED Scene value in IO-Link process data.

The LED color, brightness, effect, and effect frequency is controlled by IO-Link process data.

Classic Two LED Mode

"Idle" and "Touch" parameters of "Classic LED Control" section are used.

The Active Inputs parameter controls whether the input pins affect the selection of "Idle" or "Touch" configuration:

Active Inputs = None (3 pin mode)

TouchE1E2LED Configuration
0Not relevantNot relevantIdle
1Not relevantNot relevantTouch

Active Inputs = Pin2 (E1) (4 pin mode)

TouchE1E2LED Configuration
00Not relevantoff
01Not relevantIdle
1Not relevantNot relevantTouch

Active Inputs = Pin2 (E1) and Pin5 (E2) (5 pin mode)

TouchE1E2LED Configuration
Not relevant00off
Not relevant10Idle
Not relevant01Touch
Not relevant11Idle & Touch colors mixed