Zum Hauptinhalt springen

ISDU Indices

Access Rights: ro – Read Only, rw – Read/Write, wo – Write Only

System Command

NameIndexBytesAccessValuesDescription
System Command21wosee Events & Commands

Identification

NameIndexBytesAccessValuesDescription
Vendor Name1623roCAPTRON Electronic GmbH
Product Name1831roCANEO series10 ...Standard, Stainless Steel, Hygienic
Product ID1910roCS10X-xxxx
Product Text2019roCS10X-xxxx-xxx-xxxx
Symbol2763ro
Hardware Identification Key173429roA000010012
Serial Number2113ro
Firmware Version234roV10.x

Activation Parameters

NameIndexBytesAccessValuesDescription
Sensor Mode2611rw1 - Toggle, 2 - Dynamic, 3 - StaticToggle: Touch to switch on, touch again to switch off. Can only be set back after "Output Minimum Impulse Time" is over. Dynamic: Output is on as long as "Output Minimum Impulse Time" is set; even though the user continues touching, the output will switch off. Static: Output is on until the user is no longer touching the sensor (but is at least on for the "Output Minimum Impulse Time").
Touch Sensitivity2601rw0 - High, 1 - Middle, 2 - LowHigh: required "Actuation Strength" > 4%. Middle: required "Actuation Strength" > 14%. Low: required "Actuation Strength" > 24%.
Water Resistance2621rw0 - Basic, 1 - Enhanced, 2 - UltimateBasic: Activation by e.g. light rain/dripping water unlikely. Enhanced: Activation by water jet/high-pressure cleaner unlikely. No limitation in operability, but activation by water possible in low light conditions. Ultimate: Strongly reduced probability of activation by e.g. water jet/high-pressure cleaner. Possible limitation in operability in low light condition.
Minimum Actuation Time2632rw0 ... 65535 [ms]Time the sensor must be activated before output on Pin 4 switches, "Actuation Flag" is set to "Actuated" and "Actuation Count" goes up.
Minimum Actuation Time (Toggle OFF)2832rw0 ... 65535 [ms]Time the sensor must be touched in "Toggle" mode before output on Pin 4 turns OFF and "Actuation Flag" is set to "Idle".
Output Snap Time (Static Mode)3392rw0 ... 65535 [ms]Time after which the output snaps in (toggles); a value of 0 means no snap-in. For Static Sensor Mode only.
Output Activation Delay3242rw0 ... 65535 [ms]Time the switching of the output is delayed when the sensor has been actuated.

I/O Parameters

NameIndexBytesAccessValuesDescription
Active Inputs2711rw3 - None (3 pin mode), 4 - Pin 2 (E1) (4 pin mode), 5 - Pin 2 (E1) and Pin 5 (E2) (5 pin mode)Controls which input pins are monitored.
E1/E2 Mode2721rw0 - Active Low, 1 - Active High, 2 - Active Low/HighActive Low: Accepts a low signal as input to turn on. Active High: Accepts a high signal as input to turn on.
Output Locking3371rw0 - No locking, 1 - Release by E1, 2 - Release by E2, 3 - Release by E1 and E2Controls whether inputs E1/E2 must be active for the output signal on Pin4 to be ON when the sensor is touched.
Output Mode2731rw0 - NPN, 1 - PNP, 2 - PushPullNPN: Output signal is pulled down to 0V when output is on. PNP: Output signal is pushed up to +VDC when output is on. PushPull: Output signal is pushed up to +VDC when output is on and is pulled down to 0V when it is off.
Output NO/NC2741rw0 - NO (Normally Open), 1 - NC (Normally Closed)
Output Minimum Impulse Time2754rw10 ... 86400000 [ms]The minimal time (ms) of the output signal when the sensor is activated. The output signal cannot be interrupted. In toggle mode the sensor can only be deactivated after the minimal output signal length is over.
Output Soft Start Time (PushPull Mode)3382rw0 ... 65535 [ms]Soft Start means that the output signal ramps up with a PWM for the given time. A value of 0 means "hard" switching without PWM. Available for PushPull Output Mode only.

LED Parameters

NameIndexBytesAccessValuesDescription
LED Control Mode2931rw0 - Automatic Scene selection, 1 - Scene controlled by IO-Link Process Data, 2 - Advanced control by IO-Link Process Data, 3 - Classic Two LED ModeSee LED Control for details on each mode.
Adaptive LED Brightness2701rw0 - Off, 1 - OnIf turned "On" the sensor automatically adjusts the LED Brightness depending on the "Surrounding Brightness".
Brightness of the LED2851rw0 ... 100 [%]Serves as minimum value with automatic brightness control.

Classic LED Control (LED Control Mode = 3)

NameIndexBytesAccessValuesDescription
LED Color Idle2641rw0 - CANEO, 1 - Red, 2 - Green, 3 - Blue, 4 - Yellow, 5 - Magenta, 6 - Cyan, 10 - Orange, 11 - Violet, 13 - Off, 14 - Clean Blue, 254 - ManualColor of LED when sensor is not touched / E1 is on.
LED Color Touch2651rw0 - CANEO, 1 - Red, 2 - Green, 3 - Blue, 4 - Yellow, 5 - Magenta, 6 - Cyan, 10 - Orange, 11 - Violet, 13 - Off, 14 - Clean Blue, 254 - ManualColor of LED when sensor is touched / E2 is on.
LED Mode Idle2661rw0 - Static Ring, 1 - Flash Ring, 2 - Pulse RingBehavior of LED when sensor is not touched / E1 is on.
LED Mode Touch2671rw0 - Static Ring, 1 - Flash Ring, 2 - Pulse RingBehavior of LED when sensor is touched / E2 is on.

LED Manual Color Idle

NameIndex - SubindexBytesAccessValuesDescription
R268 - 11rw0 ... 255Red component of color
G268 - 21rw0 ... 255Green component of color
B268 - 31rw0 ... 255Blue component of color

LED Manual Color Touch

NameIndex - SubindexBytesAccessValuesDescription
R269 - 11rw0 ... 255Red component of color
G269 - 21rw0 ... 255Green component of color
B269 - 31rw0 ... 255Blue component of color

Observation & Diagnosis

NameIndexBytesAccessValuesDescription
Sensor Temperature2572ro-32768 ... 32767 [0.1 °C]
Supply Voltage2562ro0 ... 65535 [0.001 V]
Input E1 voltage2772ro0 ... 65535 [0.001 V]
Input E2 voltage2782ro0 ... 65535 [0.001 V]
MCU Voltage2792ro0 ... 65535 [0.001 V]
Charge Code2804ro0 ... 4294967295
Error Code2822ro0 ... 65535
Flash Erase Count2592ro0 ... 65535
Device Access Locks12rw